User guide

9
MODIS modul Nominal values for voltage and current
P-SA
(passive current output )
Current: 4 .. 20 mA
Working voltage: 8 .. 30V
Voltage drop : 8V at 4mA
FA-ST
(frequency/pulse/status output
or control input)
Working voltage: 6 .. 30V
Working current: < 110 mA
Voltage drop: in ON-state: < 2V at 110 mA
Leakage current in OFF-state: < 900 µA at 30V
Control input:
Input voltage LOW level: < 3V
Input voltage HIGH level: > 7V
Frequency range : 0 .. 12 KHz
DC-I
(active voltage source)
Voltage: 20V
Current 30 mA
Internal resistance: 260
Table 8: Nominal voltage and current values for the MODIS modules
IFC 090i-EEx version Part No. MODIS modules Terminal designation
Ex-i1 2.11582.01.00 P-SA FA-ST I I B1 B1
Ex-i2 2.11582.03.00 P-SA F-PA I I D D
Ex-i3 2.11582.02.00 P-SA DC-I I+ I
Ex-i4 2.11582.05.00 FA-ST F-PA B1 B1 D D
Ex-i5 2.11582.06.00 FA-ST DC-I B1+ B1
Ex-i6 2.11582.07.00 FA-ST FA-ST B2 B2 B1 B1
Ex-i7 2.11582.08.00 P-SA F-FF
I
I D
D
Ex-i8 2.11582.09.00 FA-ST F-FF B1 B1 D D
Table 9 : IFC 090i-EEx 24 Vac/dc versions.
IFC 090i-EEx version Part No. MODIS modules Terminal designation
Ex-i1 2.12253.01.00 P-SA FA-ST I I B1 B1
Ex-i2 2.12253.02.00 P-SA F-PA I I D D
Ex-i4 2.12253.03.00 FA-ST F-PA B1 B1 D D
Ex-i6 2.12253.04.00 FA-ST FA-ST B2 B2 B1 B1
Ex-i7 2.12253.05.00 P-SA F-FF I I D D
Ex-i8 2.12253.06.00 FA-ST F-FF B1 B1 D D
Table 10: IFC 090i-EEx 100-230 Vac versions.
Due to mechanical and electrical limitations, only the in table 9 and 10 listed pairs of MODIS
modules are possible. The two modules each use two terminals of the bottom four terminals
of the flameproof terminal feed-through in the dividing wall between the electronics and
terminal compartment of the signal converter housing, except for the combination with
module DC-I (only applicable for 24 Vac/dc versions), where only two of the four terminals
are used. Interconnection of the two modules, P-SA and DC-I resp. FA-ST and DC-I is made
internally.