assembly Instructions

75
Ballast loads for indoor installation
The table shows the number of ballasts to be placed on the stabiliser of the scaffold,
depending on the scaffold height and design.
Example: Scaffold centred on stabiliser, without outriggers, standing height 4.80 m: 4
bal-lasts of 10 kg each must be placed on each ballast receptacle (4 in total).
Standing
height
in m
Scaffold centred
on stabiliser with
4 outriggers
Scaffold to one
side on stabiliser
with 2 outriggers
Scaffold to one
side on stabiliser
Scaffold centred
on stabiliser
A B C D A B C D A B C D A B C D
2,8 0 0 0 0 0 0 0 0 2 2 3 3 2 2 2 2
3,8 0 0 0 0 1 1 0 0 3 3 4 4 3 3 3 3
4,8 0 0 0 0 1 1 0 0 3 3 5 5 4 4 4 4
5,8 0 0 0 0 3 3 0 0 4* 4* 6* 6* 5 5 5 5
6,8 0 0 0 0 4* 4* 1* 1* x x x x 6 6 6 6
7,8 1 1 1 1 5* 5* 1* 1* x x x x x x x x
8,8 1 1 1 1 6* 6* 1* 1* x x x x x x x x
9,8 1 1 1 1 x x x x x x x x x x x x
x = not
permitted