Installation Instructions

Step 5. Flush faucet
Remove aerator (A). Turn faucet
on for 1 minute to flush any
debris. Reconnect aerator (A).
Troubleshooting
If you have followed the instructions carefully and your faucet still does not work properly,
take the following corrective steps:
PROBLEM CAUSE ACTION
Water does not shut off
completely
Cartridge (4) may need to be
adjusted or replaced.
Remove index button (1A). Loosen set
screw (1B) with 2.5mm hex wrench (11).
Remove metal handle (1). Remove
cartridge cover (2) by hand only. Remove
locking nut with an adjustable wrench.
Remove ceramic disc cartridge (4). Check
for cracks.
8
A
A
Dripping from aerator
Washer may be missing
or not seated correctly.
Remove aerator (7). Make sure washer is
present and seated correctly.