Manual
38
Inspection report for HP cleaners
Typeplate(onhand)
Operatingmanual(onhand)
Protectivecovering,-device
Pressureline(tightness)
Pressuregauge(function)
Floatvalve(tightness)
Sprayingdevice(marking)
HP-hose/connector(damage,marking)
Safetyvalveopensat10%/20%excess
Pressurereservoir
Heatingoilline(tightness)
Solenoidvalve(function)
Thermostat(function)
Flowcontroller(function)
Powercable(damage)
Powerplug(damage)
Protectiveconductor(connected)
EmergencyOffSwitch(function)
On/Off-switch
Waterquantitysafetydevice(function)
Usedchemicals
Allowedchemicals
High-pressurenozzle
Operatingpressure............bar
Cutting-offpressure.............bar
Smokespotnumber...........acc.toBacharachscale
CO²-value...................%CO²
Efficiencyrating.............%
Conductorresist.notexceeded/value:
Insulation
Leakagecurrent:
Gunlocked
InspectionreportonannuallycarriedoutLabourSafetyInspection(UVV)accordingtothe
GuidelinesforLiquidSprayEquipment.(Thisinspectionsheetservesasproofforthecompletionof
theretestandmustbekeptcarefully!)Kränzle-TestStampMark:OrderNumberUVV200106
Scope of inspection:
ok yes no repaired
Inspection data
determ. value set value
Owner:
Address:
Typetherm:
Serialno.:
Rep.-order-no.:
TheappliancewascheckedbyanexpertaccordingtotheGuidelinesforLiquidSpray
Equipment,thedefectsfoundhavebeenrectifiedsothattheLabourSafetycanbeconfirmed
.
TheappliancewascheckedbyanexpertaccordingtotheGuidelinesforLiquidSpray
Equipment.TheLabourSafetycannotbeconfirmedunlessthedefectsfoundarerectifiedby
repairorreplacementofthefaultyparts
.
ThenextretestaccordingtotheGuidelinesforLiquidSprayEquipmenthastobecarriedout
by:
MonthYear
Place,Date Signature
Inspection result (tick)