Manual

21
Suction of detergents
with detergent supply from the suction side:
Detergentinjectiononthepressurside,asyouprobablyknowitfromotherHPcleaners,
consumeapprox.30%ofthecleaningenergy,nomatteriftheyareusedornot.Duetothe
watertankfittedtotheKränzlethermcleanersitisnowpossibletodirectlysuckthe
detergentintothepumpthusreducingoutputlossandincreasingtheefficencyconsiderably
.
The detergents are applied without having to reduce the working pressure
.
1.
Placedetergentfilterintodetergent
container
.
2.
Dosingofdetergentisdonebyturning
thedetergentvalve
.
3.
Byclosingthedeter-
gentvalvethesupplyof
detergentisstopped
.
4.
Afterhavingused
detergentsrinsethe
appliancewithopenspraygunandclear
waterforatleast2minutes.
Only open the dosing valve, if the detergent sieve is placed in a liquid.
Sucked air leads to destruction of the pump seals! No guarantee!
Keep detergent-ph-value neutral 7 - 9!
Observe specifications of detergent manufacturer!
e.g.: protective equipment, rules for waste water treatment etc.
Never suck in liquids containing solvents like varnish solvents, petrol,
oil or similar liquid! Observe specifications of detergent manufacturers
!
Seals inside the appliance are no resistant against solvents! The spray
mist of solvents is highly inflammable, explosive and poisonous.