Manual

15
Kränzle technology
Theinnovativenewpercentmodenowletstheuserspecifytheswitchingdurationofthe
heaterinpercentusingthe"+"and"-"buttons(Pos.3+4)(100%beingthemax.temperature)
ratherthansettingthedesiredtemperature.Nowtheresultofthesettingmustbechecked
by using the "Actual" temperature display. If the desired temperature has not yet been
reached,thepercentagemustbeincreased.
Bysettingpercentagesoftheheatingduration,thetemperatureofthehighpressurejetis
keptconstantinaverynarrowrange.
Thelastvaluesetisalsosavedaftertheunitisswitchedoffinpercentmode.
Operating hour meter
Thecleanerisequippedwithanoperatinghourmeter.
Ifduringnormaloperationthemomentaryoperatingmodebutton("°C"or"%")isactuated
formorethen2seconds,theoperatingtimeofthepumpisdisplayedfor5secondsand
afterwardsthecombustiontimefor5secondsaswell.Thereafterthedisplayshowsthe
originalvaluesagain.
As long as the operating hours are displayed no further inputs on the monitor are
possible.
Theoperatingtimeisdisplayedinhours[h]eitherinthe“TARGET”orinthe„ACTUAL“
window.The1000and100hoursaredisplayedinthe„TARGET“windowandthe10,1and
1/10hoursinthe“ACTUAL”window:
Pumpoperatingtime: Target-Display:P99 Actual-Display:99.9for9999.9h
Combustiontime: Target-Display:F99 Actual-Display:99.9for9999.9h
e.g.:F0027.3=Cumbustiontime27hoursand18minutes