Weekly, or after approx. 40 hours of operation:
- Checktheoillevelofthehighpressurepump.Iftheoillevelistoolow,addoiluntil
theoillevelisbetweenthetwomarkingsontheoilmeasuringrod.
Changetheoilifithasagreyorwhitishappearance.Theoilshouldbe
disposedofresponsibly.
- Checkthewaterfilterinfrontofthefloatvalveinthewatertankandthefuelfilter
infrontofthesolenoidvalve.Cleanthefiltersifnecessary.
Yearly, or after approx. 500 hours of operation:
- Desulphuriseanddecarbonizetheheatingcoil.
- Checkheatingcoilforcalcification,decalcifyifnecessary.
- Checktheoilburnerandignitionsystem.
- Cleantheoilnozzle,oilfilter,solenoidvalveandfilter,cleanandadjusttheignition
transformer,ignitioncableandignitionelectrodesandreplacedefectiveparts.
- Changetheoil
Oil leakage: If oil leaks out, go to the nearest customer service (dea-
ler) immediately. (Environmental damages, transmission damages,
loss of guarantee.)
In case of increased humidity or fluctuations in temperature develop-
ment of condensed water is possible; if the oil turns grey, you must
change it.
Care and Maintenance
The machine must be disconnected from the power supply when ser-
vicing work is being carried out. The main switch should be in
position "0" and the plug out of the socket.