Manual

11
Please note - important!
Insufficient quantity of electricity
Iftherearetoomanycollectorsinyour
proximityconnectedtothenetworkatthe
sametime,theavailablevoltageandthe
currentintensitymaydecline.
Consequentlythemotorofthehigh-pres-
surecleanerdoesnotstartorevenblows.
Thepowersupplymayalsobeinsufficient
ifthepowercableistoolongortoothin.If
extensioncablesaretoolong,thismay
leadtoavoltagedropcausing
malfunctionsorstart-updifficulties.
Electrical connection
Themachineissuppliedwithanelectricalpowercablewithplug.Themainsplugmust
befittedtoastandardgroundedsocketwitha30 mAresidualcurrentoperateddevice.
Thesocketmustbeprotectedwitha16Adelayactionfuseonthemainsside
.
When
usinganextensioncable,thismusthaveanearthedleadwhichisproperlyconnectedto
thesocket.Theconductorsintheextensioncablemusthaveaminimumcrosssectionof
1.5 mm².Plugconnectionsmustbeofaspray-proofdesign,andmaynotbelocatedon
awetfloor.Withextensioncablesofmore than 10 mtheminimumcrosssectionmust
be2.5 mm!Whenusingacabledrum,alwayskeepthecablewoundasfaraspossible
.
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.