Therm 635-1 Manual
6 7
Explanatory symbols
Explanatory symbols used on the control panel
Step 2:
Connect water hose to water inlet.
Open water tap.
Step 1:
Screw high-pressure hose down and pressure-
tight using safety trigger gun and lance.
Prior to putting the machine into operation
make sure that all safety instructions be
observed.
Attention: For safety reasons switch off main
switch after completing the washing procedure
(= supply isolation)
Prior to putting the machine into operation
make sure that all safety instructions be
observed.
Step 3:
Connect to circuit (see technical data).
Step 4:
Usage as a cold water high-pressure cleaner.
Switch on high-pressure cleaner at main switch
with opened safety trigger gun.
Start with cold water cleaning process.
Step 5:
Usage as a hot water high-pressure cleaner.
Switch on high-pressure cleaner at heater
switch with opened safety trigger gun. Start
with hot water cleaning process.
Controlling the temperature
Set the desired temperature at the digital ther-
mostat by pushing the plus and minus buttons
(Min. temperature 40 °C). Settings are possible
in cold water and hot water operation.
Explanatory symbols used on the short instruction manual
Explanatory symbols