Product Manual

26
Particular rules, directives and
inspections
Inspections performed by Kränzle
-measurementofearthlineresistance
-measurementofvoltageandcurrent
-inspectionoftensionconsistencywith+/-1530V
-pressurecheckofheatingcoilat300bar
-visualandfunctionalcheckaspertheinspectionsheetprovided
-exhaustfumeanalysis(seeteststripsprovided)
Guidelines for liquid sprayers
Themachineconformswiththe"Guidelinesforliquidsprayers".Theseguidelinesare
issuedbytheorganisationoftradeassociationsandmaybeobtainedfromCarl
Heymann-VerlagKG,LuxemburgerStr.49,50939Köln.Theseguidelinesspecifythat
thismachineistobeinspectedbyqualifiedpersonnelwhenevernecessary,butnoless
thanonceevery12months.Theseinspectionsmustberecordedintheinspectionlogat
theendofthismanual.
Pressure container and steam boiler directives
Kränzlehighpressurecleaningequipmentconformstothepressurecontainerandsteam
boilerdirective.Noconstructionapproval,notificationoflicenceandtakeoverinspection
arerequired.Thewatercapacityislessthan10l.
Duties of owner
Theowneristoensurethatallsafety-relevantcomponentsareinaserviceable
conditionbeforethesprayerisused.(e.g.,safetyvalves,hoseandelectriccables,spray
equipmentetc).
Emission control legislation
Withstationaryinstallation,theemissionlevelsofthemachinemustbecheckedoncea
yearbyaqualifiedorganisationorpersonaccordingtoGermanlaw.Thefirstinspection
mustbecarriedoutfourweeksafterthemachineiscommissioned.Theownerisrespon-
sibleforhavingtheinspectionperformed.