KQ1000TST Manual
22 23
8. After insertion of the lance, release
retaining sleeve and make sure that
the lance is in a secure position.
Grease quick release nipple regularly
using acid-free grease.
7. First pull back the retaining sleeve of
the safety trigger gun, then insert lance
into the plug coupling sconnection of
the safety trigger gun.
6. Mount the grey rotating screw con-
nection of the high-pressure hose onto
the trigger gun incorporating a safety
catch. Afterwards screw together
ensuring a snug and pressure-tight fit.
5. For high-pressure cleaners with hose
drum, please loosen the fixation and
then completely unwind the high-pres-
sure hose. For high-pressure cleaners
without hose drum the high-pressure
hose included in the scope of the
delivery must be screwed with the pump
outlet in a tight and pressure tight man-
ner. Unwind high-pressure hose straight
and without nooses. The high-pressure
hose may leave signs of abrasion on
some floors. Alternatively, please also
find non-marking high-pressure hoses
in our range.
Putting into operation
9.
Check water inlet filter for cleanliness
prior to putting the high-pressure
cleaner into operation.
Manually unscrew plug-in coupling.
Take out the water inlet filter using
needle nose pliers and thoroughly
rinse it with clear water and clean
it with the other parts. If the sieve is
dirty, water cannot get through and
pressure will not build up.
10.
Connect water hose to water inlet
(mi-
nimum requirements; 5 m hose length,
cross-section ¾", 10 bar). The high pres-
sure cleaner may be connected to a water
mains (1-10 bar pre-pressure) with
either cold or hot water (up to 60 °C).
The large quadro series provides the
opportunity of sucking in water out
of a container (see direct suction).
Check the water inlet sieve for damage. Do not operate the
high-pressure cleaner without or with a damaged filter.
Be careful when using hot water!
When running your high-pressure cleaner with hot water of 60 °C raised
temperatures occur. Do not touch the metal parts of the high-pressure
cleaner without safety gloves!
11. Each time check oil level at the oil
dipstick prior to putting the high
pressure cleaner into operation.
Oil level must reach until the upper
edge of marking "OK“.
Putting into operation
The plug coupling must not be actuated/handled during operation!
High risk of injury!
Prior to insertion, check plug coupling connection of lance for
cleanliness (sand, dirt ..) and use clear water to clean, if necessary.
Impurities may damage the sealing in the plug coupling.
When using high-pressure hose extensions take care that the max.
length of 20 m is not exceeded!
Accessories may only be connected to a Kränzle-approved trigger gun
with safety catch.