Manual
40
for KRÄNZLE - High Pressure Cleaners
The high pressure cleaner must be inspected
by an expert every 12 months.
Appliance No.: Type of appliance:
The following must be checked:
1. Safety features
a) Manometer
b) Safety valve (pressure control)
c) Operating pressure
d) Cut out pressure (max. 10% above
operating pressure)
e) Low pressure with closed gun
2. General condition
a) High pressure hose
b) Cable, plug, switch (VDE)
c) Spray gun, spray accessories.
d) Motor
e) Oil level
Result of
inspection:
Date of inspection:
Faults rectied,
Stamp and signature
Excerpt from the Guidelines for Liquid Spray Equipment (ZH 1/46) by the Central Ofce of the Profes-
sional Trade Association.
Inspection:
Liquid spray equipment should be inspected for safe operation by a qualied person whenever neces-
sary, but no less than every 12 months. The maker’s or supplier’s instructions must be followed. The
inspection intervals may be extended if the equipment is not in active use.
The results of inspections must be recorded in writing and presented to the respective authorities on
demand. There is no set form for these records.
The information in the operating instructions are a part of
the inspection
Inspection report