Manual

21
do it yourself !
Nozzle dirty or sticky!
Pressure gauge does not show full pressure
Water comes out in spurts.
If you do not use the high-pressure cleaner for some time the valves can stick
The high-pressure hose vibrates
Straighten a
paper clip...
When a valve is blocked,
the gauge
shows little
pressure or
no pressure
at all,
or the high
pressure
hose vibra-
tes!
Open the valve
with a socket
wrench...
and remove the
valve screw, the
valve and the
o-ring.
Replace the rubber o-ring.
and remove the
dirt from the valve
- the valve inside
must be closed.
Retighten the valve
screw
...and
repeat on all 6
valves.
Now it works
as well as
before!