Manual
External suction
If water is to be sucked from an external container for the high pressure cleaner,
the connection hose between the high pressure pump and the water tank must be
screwed off and the suction hose must be connected directly to the pump.
Make sure that the water is clean. Use the Kränzle suction hose with suction lter.
(Order N°. 15.038 3)
Maximum suction height 2.5 m, maximum water
temperature for direct suction: 60°C
(see technical data on page 2)
Preparation for use
5. The machine must be connected to the water line
with cold water or up to 60° C warm water (see
page 2).
The hose cross section must be at least 3/4" =
16 mm (free passage). Filter 1 must always be
clean.
Please make sure that the lter is clean before
using your high pressure cleaner.
CAUTION !
When running your high pressure cleaner with hot water of 60° C
raised temperatures occur.
Do not touch the pump without safety gloves!
13
1
UndercarriageUndercarriage