K2160TST 10A Manual

22 23
7. Check water inlet filter for cleanliness
prior to putting the high-pressure
cleaner into operation.
Manually unscrew plug-in coupling.
Take out the water inlet filter using
needle nose pliers and thoroughly
rinse it with clear water and clean
it with the other parts. If the sieve is
dirty, water cannot get through and
pressure will not build up.
8. Connect water hose to water inlet (mi-
nimum requirements; 5 m hose length,
cross-section ¾", 10 bar). The high pres-
sure cleaner may be connected to a
water mains (1-10 bar pre-pressure)
with either cold or hot water (up to
60 °C). The K 2000-series provides the
opportunity of sucking in water out
of a container (see direct suction).
Check the water inlet sieve for damage. Do not operate the
high-pressure cleaner without or with a damaged filter.
Be careful when using hot water!
When running your high-pressure cleaner with hot water of 60 °C raised
temperatures occur. Do not touch the metal parts of the high-pressure
cleaner without safety gloves!
9. Each time check oil level at the oil
dipstick prior to putting the high
pressure cleaner into operation.
(Take care that cleaner is in horizontal
position!) Oil level must reach until
the upper edge of marking "OK“.
Putting into operation Putting into operation
6. After insertion of the lance, release
retaining sleeve and make sure that
the lance is in a secure position.
Grease quick release nipple regularly
using acid-free grease.
5. First pull back the retaining sleeve
of the safety trigger gun, then
insert lance into the plug coupling
sconnection of the safety trigger gun.
4. Mount the grey rotating screw con-
nection of the high-pressure hose onto
the trigger gun incorporating a safety
catch. Afterwards screw together
ensuring a snug and pressure-tight fit.
The plug coupling must not be actuated/handled during operation!
High risk of injury!
Prior to insertion, check plug coupling connection of lance for
cleanliness (sand, dirt ..) and use clear water to clean, if necessary.
Impurities may damage the sealing in the plug coupling.
When using high-pressure hose extensions take care that the max.
length of 20 m is not exceeded!
Accessories may only be connected to a Kränzle-approved trigger gun
with safety catch.
3. For high-pressure cleaners with hose
drum, however, it must be uncoiled
completely. For high-pressure cleaners
without hose
drum the high-pressure
hose included in the scope of the
delivery must be screwed with the
pump outlet in a tight and pressure
tight manner. Unwind high-pressure
hose straight and without nooses. The
high-pressure hose may leave signs
of abrasion on some floors. Alterna-
tively, please also find non-marking
high-pressure hoses in our range.