Product Manual
Electrical connection
The machine is supplied with an electrical power cable with plug. The mains plug must be
fitted to a standard grounded socket with a 30mA residual current operated device. The
socket must be protected
For K2017, K2017T with a 15A or 16A delay action fuse on the mains side.
For K2017, K2017 T, K2020, K2020 T with a 20A delay action fuse on the mains side.
When using an extension cable, this must have an earthed lead which is properly connected
to the socket. The conductors in the extension cable must have a minimum cross section
of AWG14 for K2017, of AWG12 for K2020. Plug connections must be of a spray-proof
design, and may not be located on a wet floor. With extension cables of more than 10 m the
minimum cross section must be AWG12 for K2017, of AWG10 for K2020! When using a
cable drum, always keep the cable wound as far as possible.
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.
11
Connected load:
Kränzle 2017, 2017 T: 115 V ~, 60 Hz
Kränzle 2020, 2020 T: 115 V ~, 60 Hz
Insufficient quantity of electricity
If there are too many collectors in your
proximity connected to the network at
the same time, the available voltage
and the current intensity may decline.
Consequently the motor of the
high-pressure cleaner does not start or
even blows.
The power supply may also be insufficient
if the power cable is too long or too
thin. If extension cables are too long,
this may lead to a voltage drop causing
malfunctions or start-up difficulties.