Product Manual
9
Preparation for use
1. Check oil level.
There are two
possibilities for checking the oil level of the pump:
a) Oil must be visible in the viewingwindow
b) The oil level must be between the two
markings on the oil dipstick.
To check the oil level, loosen the oil cover screw and take out the oil dip stick. The
oil level must be between the two markings.
2. Connect the high pressure lance
or dirtkiller to the spray gun.
4. The machine must be connected to the water line with cold water or up to
60
°°
°°
° C warm water (see page 2).
The hose cross section must be at least 3/4" = 16 mm (free passage).
It is recommended to install a water filter prior to the cleaner.
(Kränzle order no.: 13.300 3)
3. Unroll hose without kinks and connect with
handgun and pump. Max. extension 20m-HP
hose or 2 x 10m with hose connections.