Product Manual

3
Preparation for use
Stationary cold water high pressure cleaner
The stationary wall-mounted systems are supplied with a stainless steel housing and
equipped with an AQ pump (W11/135 with APG pump) and 10m steel fabric heavy
duty hose.
Pressure fully adjustable, automatic total-stop feature.
After the gun is closed, the device continues to run for a time and then cuts out. It
restarts when the gun is opened. Incorrect operation by unauthorised persons is
therefore not possible. The factory setting is 30 seconds. The device is connected
to a water supply with advance pressure. Temperatures of up to 60 °C are possible.
Features
Stainless steel housing,
10 m heavy duty hose with gun,
lance 800 mm
control nozzle and HP nozzle.
Preparation for use
Connect to suitable water supply, open the water tap.
Switch on high-pressure cleaner. The pump is running and the pressure is built up.
If the gun remains closed, the cleaner continues to run for another 30 seconds and
then switches automatically into standby.
As soon as you presser the trigger of the gun the high-pressure pump starts.
After closing the gun, it continues to run for approx. 30 seconds, and then switches
back to standby mode.
The device continues to run once the trigger is pressed during the 30 seconds.
1 Water inlet connection
2 High-pressure outlet
3 Press. gauge with glycerin filling
4 On-/ Off switch
Function
2
1
34
If you use the HP cleaner for the first time or if you have not worked
with your cleaner for a longer period of time, the machine has to be
deaerated by opening and closing the gun various times.