K1152TST Manual
24 25
1. Place chemicals filter into container
with additives
2. To reach the low pressure push Vario
nozzle to the front so that the injector
can suck in the additives.
3. When pushing the Vario nozzle
backwards, chemicals supply is
automatically stopped, high-pressure
cleaner changes in high-pressure mode.
Let additives take effect and then spray
off with high-pressure.
Due to their small base, the compact and
mobile Kränzle high-pressure cleaners are
easy to store.
Applying additives Taking out of operation
Suction of additives
For K 1152-series a built-in injector provides the facility to suck in additives. By pushing
the Vario-Jet lance to the front the high-pressure cleaner is adjusted to low pressure
and a vaccum is build up in the injector. Thus the additives can be sucked in via
the connected suction hose with filter.
1. Switch off the high-pressure cleaner
2. Cut off the water supply
3. Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5. Remove high-pressure hose and safety trigger gun
6. Emptying high-pressure pump: Hold high-pressure hose and switch
motor on until water jet stops escaping at the outlet.
7. Pull the plug from the socket
8. Clean high-pressure hose and wind up without loops
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Store high-pressure cleaners in frost-free rooms in winter
Frost protection
For protecting the high-pressure cleaner against frost please empty it completely.
Separate high-pressure cleaner from water supply and switch it on.
By opening
the trigger gun the high-pressure pump presses water out of the high-pressure
cleaner. However, do not allow the device to operate without water for more
than one minute.
The additive must reveal a neutral pH value of 7-9. This machine has been
designed for use of cleaning agents supplied or specifically recommended
by the manufacturer. The use of other cleaning agents or chemicals may
impair the safety of the machine. Observe and comply with relevant
regulations, e.g. directives governing protective equipment, waste-water
regulations, etc.
Attention solvents!
Never suck in liquids containing solvents like varnish solvents, petrol,
oil or similar liquids! Seals inside the high-pressure cleaner are no
resistant against solvents! The spray mist of solvents is highly
inflammable, explosive and poisonous.