20 21
The high-pressure cleaner must be operated in horizontal position!
It is imperative that safety instructions be observed during
use of the high-pressure cleaner.
Neither set up or operate the K 1152-series in rooms where there is a
risk of fire or explosion nor put it into puddles. Do not use the high-
pressure cleaner under water. If, none the less, the high-pressure
cleaner is operated in a hazardous area, the applicable safety
regulations are to be observed.
1. Use the supplied screws to fasten the
lower cable retractor of the power
supply cable in the place provided on
the frame.
3. Move high-pressure cleaner to the
job site. The K 1152-series is a movable
high-pressure cleaner with sturdy trol-
leys ideally suited for difficult terrain
and stairs.
Putting into operation Putting into operation
2. For high-pressure cleaners with hose
drum the enclosed hand crank mus be
applied prior to first operation. For this
purpose, please set up the high-pressure
cleaner. Plug the hand crank onto the
hexagon and attach it with the
enclosed screw and washer.
7. After insertion of the lance, release
retaining sleeve and make sure that
the lance is in a secure position.
Grease quick release nipple regularly
using acid-free grease.
6. First pull back the retaining sleeve
of the safety trigger gun, then
insert lance into the plug coupling
sconnection of the safety trigger gun.
5. Mount the grey rotating screw con-
nection of the high-pressure hose onto
the trigger gun incorporating a safety
catch. Afterwards screw together
ensuring a snug and pressure-tight fit.
The plug coupling must not be actuated/handled during operation!
High risk of injury!
Prior to insertion, check plug coupling connection of lance for
cleanliness (sand, dirt ..) and use clear water to clean, if necessary.
Impurities may damage the sealing in the plug coupling.
When using high-pressure hose extensions take care that the max.
length of 20 m is not exceeded!
Accessories may only be connected to a Kränzle-approved trigger gun
with safety catch.
4. For high-pressure cleaners with hose
drum, however, it must be uncoiled
completely. For high-pressure cleaners
without hose
drum the high-pressure
hose included in the scope of the
delivery must be screwed with the
pump outlet in a tight and pressure
tight manner. Unwind high-pressure
hose straight and without nooses. The
high-pressure hose may leave signs
of abrasion on some floors. Alterna-
tively, please also find non-marking
high-pressure hoses in our range.