Manual

18 19
Check the water inlet sieve for damage. Do not operate the
high pressure cleaner without or with a damaged filter.
10. Switch on high pressure cleaner with
opened safety trigger gun. Bleeding
of the high pressure cleaner: Pull and
release trigger of safety trigger gun
several times. Start cleaning task.
It is imperative that safety instructions be observed during
use of the high pressure cleaner.
9. Connect to circuit (see technical data).
11. When using the filth killer lance make
sure that lance points downward when
starting.
7. Check water inlet filter for cleanliness
prior to putting the high pressure
cleaner into operation.
When inside filter is contaminated,
remove filter and follow step 7.1.
If the sieve is dirty, water cannot get
through and pressure will not build up.
8.
Connect the water hose to water inlet
sieve (minimum requirements; 5 m
hose length, cross-section ¾", 10 bar).
The high pressure cleaner may be
connected to a water mains (1-10 bar
pre-pressure) with either cold or hot
water (up to 60 °C).
7.1 If contaminated, remove the filter and
thoroughly rinse it with clear water
and clean it with the other parts.
Be careful when using hot water!
When running your high pressure cleaner with hot water of 60 °C raised
temperatures occur. Do not touch the metal parts of the high pressure
cleaner without safety gloves!
Putting into operation Putting into operation
Do not touch the mains plug or any live parts with wet or moist hands.