Manual

Circuit diagramme 400V / 50Hz
29
Excess
tempe-
rature
release
Photo cell
Float switch (fuel)
Flow controller
Pressure switch Burner release
Pressure switch Motor Start/Stop
F1
F2
L1
L2
Thermostat with
rotary switch
Connection via
grounding plug
230 V / 50 Hz
Master switch
A.C. motor
High pressure pump
Excess
current actuator 15 A
Switch
Heating
Burner
motor
Ignition
transformer
Fuel
valve
Ord.-No:
44.836
Sensor line
Thermostat
Thermostat
with rotary
switch
Pressure switch
Motor Start/Stop
Pressure switch
Burner release
Flow controller
Burner release
Sensor
Water temperature
Float switch (fuel)
Photo cell
Flame monitoring