User's Manual
Table Of Contents
Kramer Electronics Ltd.
VM-3DT - Operating the VM-3DT
9
Acquiring an EDID
You can acquire the EDID from a connected output or set the VM-3DT to the default EDID.
To acquire an EDID, press the EDID SETUP button as follows:
1. Press EDID SETUP once.
The OUTPUTS CONNECTED LEDs flash to indicate the current EDID used: 1, 2, or 3,
or all if the default EDID is currently used.
2. Press EDID SETUP again to enter the EDID read mode and then press repeatedly to
cycle through the EDID source options until the desired EDID source is reached:
OUT 1 -> OUT 2 -> OUT 3 -> all LEDs flash (for a default EDID).
3. Wait a few seconds for the VM-3DT to read the EDID.
When complete, all LEDs return to display the present output connection status.
N
ote that if an unconnected output is chosen or the EDID cannot be read, the VM-3DT loads
the default EDID
.
VM
-3DT supports Kramer EDID Designer (via the mini USB port), available at our website:
Kramer EDID Designer
.
I
n order to use the mini USB port , you need to download and install the Kramer USB
driver from our
web site at: www.kramerav.com/support/product_downloads.asp.
Forcing the RGB Mode
VM-3DT can acquire EDID in normal mode (default) or in RGB mode (EDID supports only
RGB color space).
To enter RGB-only mode:
1. Press and hold EDID SETUP .
The output LEDs flash 4 times and then turn off.
2. If required, read the EDID (see Acquiring an EDID, on page 9
).
To return to the normal mode:
1. Press and hold EDID SETUP .
The output LEDs light once and then turn off.
2. If required, read the EDID (see Acquiring an EDID, on page 9
).
Upon power on, the output LEDs flash according to their EDID mode:
four times for RGB
mode
and once for normal mode.