7.3.2  Recalling a Setting 
To recall a setting, do the following: 
1.  Press the RCL button. The RCL button flashes. 
2.  Press the Output #. The LED Output display # flashes
1
, displaying what was 
previously stored. 
3.  Press the RCL button again. This recalls the stored data. 
By design
2
, you cannot recall data that is stored in a particular unit from a 
different unit. Each unit, even when set to the IN SYSTEM mode, stores its 
own data separately. 
7.3.3  Locking and Unlocking Settings 
The PC includes a flexible locking
3
 mechanism to safeguard settings on the 
switchers. To prevent changing the settings accidentally
4
, lock your 
switchers. Unlocking releases
5
 the protection mechanism. 
From the PC you can lock and unlock the following: 
  A specific switcher 
  All switchers 
Table 6: Push Button Sequence Summary 
   Lock  Unlock 
Specific Switcher 
TAKE + MACHINE IN SYSTEM # + STO  TAKE + MACHINE IN SYSTEM # + RCL 
All Switchers 
TAKE + ALL + STO  TAKE + ALL + RCL 
8  Technical Specifications 
Table 7, Table 8, and Table 9 list the technical specifications for the 88 
Series switchers. 
1 At this stage, pressing a different # changes the Output # 
2 On one occasion the same unit can function in the standalone mode, and on another occasion in the IN SYSTEM mode 
3 Locking means that the front panel is locked. The switcher still operates via the PC 
4 Especially if the system is complex and the switchers are stored on a rack in another room 
5 Restarting a switcher also releases the protection mechanism (without wiping out the switcher settings) 