User manual

Communication Parameters
17
17
9 Communication Parameters
Table 3: Communication Parameters
RS-232
Protocol 2000
Baud Rate: 9600
Data Bits: 8
Stop Bits: 1
Parity: None
Command Format: HEX
Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81
Ethernet
Default Settings Reset Ethernet Default Settings
IP Address: 192.168.1.39 Power cycle the unit while holding in the Factory Reset
button, located on the rear panel of the unit.
TCP Port #: 5000
10 Hex Table
Table 4 lists the Hex values for a single machine (MACHINE # 1):
Table 4: VS-44H Hex Codes for Switching via RS-232/RS-485
OUT 4
OUT 3
OUT 2
OUT 1
01
81
84
81
01
81
83
81
01
81
82
81
01
81
81
81
IN 1
01
82
84
81
01
82
83
81
01
82
82
81
01
82
81
81
IN 2
01
83
84
81
01
83
83
81
01
83
82
81
01
83
81
81
IN 3
01
84
84
81
01
84
83
81
01
84
82
81
01
84
81
81
IN 4