Manual
KRAMER: SIMPLE CREATIVE TECHNOLOGY 
MENU Commands 
38
11.3  Choosing the SWITCHING METHOD Setting 
Section 
 11.3.1 describes the SWITCHING METHOD settings for 
standalone units and large matrices. Section 
 11.3.2 describes how to 
configure a SWITCHING METHOD. 
11.3.1 Understanding the SWITCHING METHOD Settings 
Setting the unit as a Stand-Alone UNIT provides a choice of three 
SWITCHING METHOD settings: 
•  NoVIS - switching occurs immediately after completion of front 
panel or dry-contact operation or immediately after receiving an 
RS-232 or RS-485 command, or an IR command. The switching 
is independent of the vertical reference 
•  EXT (external sync) - switching occurs during the vertical 
interval of the video reference signal connected to the IN SYNC
1
connector (this signal should be properly terminated via the 
TERM button
2
•  INT# 1 (internal sync) - switching occurs during the vertical 
interval of the video reference signal connected to IN # 1 
) 
Setting the unit as a Large Matrix (instead of as a Stand-Alone UNIT) provides 
a choice of 4 SWITCHING METHOD settings: 
•  NoVIS, EXT or INT# 1 (as described above) 
•  MTX (SYNC from Matrix) - the vertical interval of the video 
reference (selected on one unit in the Large Matrix system) is 
present on the “SYNC” RS-485 terminal block connector
3
To choose the MTX (SYNC from Matrix) setting
. This 
reference signal applies to all switchers in the multi-switcher 
system and facilitates switching all VS-162/VS-1616 series units 
simultaneously 
4
Figure 
17
 as the example in 
 illustrates: 
•  Connect the RS-485 terminal block connectors
5
•  Connect and set the video reference signal on one of the video 
units to EXT (external sync) or INT# 1 (internal sync) 
 between each 
switcher in the multi-switcher system 
1 Item 1 in Figure 1 
2 Item 3 in 
Figure 1 
3 Item 5 in 
Figure 1 
4 This sets the matrix sync configuration from another (Master) machine 
5 Via a straight connection of all 4 PINS 