Owner's manual
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Communication Protocols
62
For commands sent from some non-Kramer controllers like Crestron, some
characters require special coding (such as, /X##). Refer to the controller manual.
16.1.5 Command Forms
Some commands have short name syntax in addition to long name syntax to allow
faster typing. The response is always in long syntax.
16.1.6 Chaining Commands
Multiple commands can be chained in the same string. Each command is delimited
by a pipe character (“|”). When chaining commands, enter the message starting
character and the message closing character only once, at the beginning of the
string and at the end.
Commands in the string do not execute until the closing character is entered.
A separate response is sent for every command in the chain.
16.1.7 Maximum String Length
64 characters
16.1.8 Table of Protocol 3000 Commands
Command
Short
Form Description Permission
# Protocol handshaking End User
BUILD-DATE? Read device build date End User
CPEDID
Copy EDID data from the output to the input
EEPROM
Common
DISPLAY Valid / Invalid output Switch
DISPLAY? Read if output is valid Switch
FACTORY Reset to factory default configuration Common
FCT-MODEL Set model name Common-mandatory
FCT-SN Set Serial Number Common-mandatory
GEDID Read EDID data Common
GEDID-EXT
Read EDID data from external device
connected to output
Common
HELP List of commands Common-mandatory
IDV Visual identify device Common
INFO-IO? Read in/out count Switch
INFO-PRST? Read max preset count Switch
LDEDID Load EDID data Common
LDFW Load new firmware Common
LOCK-FP LCK Lock front panel Common
LOCK-FP? LCK? GET Lock front panel Common
MODEL? Read device model End User
P2000 Switch to protocol 2000 Common