User's Manual
66 
VP-770 - The VP-770 RS-232 Communication Protocol 
1st 
Level 
2nd Level 
3rd Level 
4th Level 
Range 
Func. 
Note 
Group C 
None 
0 (read only) 
293 
Activate CH1 
1 
Activate CH2 
2 
Bypass 
3 
Group D 
None 
0 (read only) 
294 
Activate CH1 
1 
Activate CH2 
2 
Bypass 
3 
Process 
Deinterlacing 
Method 
Line Doubler 
0 
311 
Volatile parameter 
unavailable in 
progressive scan 
Motion Adaptive 
1 
Sync 
Current Field 
0 
312 
Unavailable in 
progressive scan. 
Older Field 
1 
Film Mode 
Off 
0 
320 
Unavailable in 
progressive scan 
Follow Input 
1 
24PsF Mode 
2 
Diagonal 
Correction 
0:3 
330 
Unavailable in 
progressive scan. 
Unavailable when 
deinterlacing sync 
is older field 
MD Sensitivity 
LEVEL1 
0 
340 
Unavailable in 
progressive scan 
LEVEL2 
1 
LEVEL3 
2 
LEVEL4 
3 
LEVEL5 
4 
Picture 
Brightness 
-400:400 
410 
In the OSD menu 
the range appears 
as -80:80 
Contrast 
0.1:1.6 
420 
Color 
0.1:1.6 
430 
Color 
Correction 
Blue 
0:4 
441 
Green 
0:4 
442 
Flesh 
0:4 
443 
Black Level 
-80:80 
450 
Gamma 
Mode 
Gamma Off 
0 
460 
Gamma 0.4 
1 
Gamma 0.8 
2 
Gamma 1.2 
3 
Gamma 1.6 
4 
Gamma 2.0 
5 
Gamma 2.4 
6 
Gamma 2.8 
7 
Dither 
Mode0: Disable error diffusion  
0 
470 
Mode1: In-frame 8:6 conversion 
1 
Mode2: Intra-frame 8:6 conversion 
2 
Mode3: In-frame 10:8 conversion 
3 