User's Manual
12 FC-5 - Configuring the Kramer FC-5 Manager Software
Hardware flow control is not required for this unit. In the rare case where a
controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on
the controller side.
Method B (Figure 11
)—Connect the RS-232 9-pin D-sub port on the unit via a
straight (flat) cable to the null-modem adapter, and connect the null-modem
adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually
contains all nine wires for a full connection of the D-sub connector. Because the
null-modem adapter (which already includes the flow control jumpering described
in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to
decide whether to connect only these 3 pins or all 9 pins.
Figure 11: Straight Cable RS-232 Connection with a Null Modem Adapter
5.4 Setting the DIP-Switches
Figure 12 defines the DIP-switches, which are used to select the translation
drivers.
DIPs Set as follows:
1, 2 Determines the settings of the translation set
3, 4 Reserved
Figure 12: Translation Set DIP-Switches
Translation
Set 1
Translation
Set 2
Translation
Set 3
Translation
Set 4
Generic to
Kramer 2000
(default)
Sierra Video Systems
to Kramer 2000
1 OFF ON OFF ON
2 OFF OFF ON ON
1
2
6
3
7
4
8
5
9
to PC
Null-Modem
Adapter