Instruction Manual
Technical Specifications 
9
7  Technical Specifications 
Table 6 includes the technical specifications: 
Table 6: Technical Specifications
1
 of the FC-4001 Format Converter / TBC 
INPUTS: 
1 composite video - 1 Vpp / 75 on a BNC connector 
1 YC - 1 Vpp/75 (Y), 0.3Vpp/75 on a 4p connector 
1 component - Y/R-Y/B-Y (1Vpp/0.7Vpp/0.7Vpp) /75 (or RGB/S) on BNC 
connectors 
1 SDI: SMPTE-259M, ITU-R BT.601 on a BNC connector 
1 SYNC (Genlock): Looped 75 / Hi-Z on BNC connectors 
OUTPUTS: 
1 composite video on a BNC connector 1 Vpp/75 
1 YC video on 2 BNC connectors: Y 1 Vpp/75, and C 0.3Vpp/75 
1 component or RGB/S video on BNC connectors 1Vpp/0.7Vpp/0.7Vpp/75 
1 SYNC on a BNC connector 
2 SDI: SMPTE-259M, ITU-R BT.601 on BNC connectors 
VIDEO STANDARDS:  PAL-B/D/G/H/I/M/N, NTSC-3.58/4.43, SECAM 
DIGITAL RESOLUTION:  10 bits 
BANDWIDTH (-3dB):  0.5dB to 5MHz, Fully Loaded 
DIFF. GAIN:  1% 
DIFF. PHASE:  1 Deg. 
K-FACTOR:  1% 
S/N RATIO:  63dB 
LUMA NON-LINEARITY:  1% 
CHROMA / LUMA DELAY:  1ns 
CONTROLS:  Front-panel and RS-232; SCH phase, SYNC phase, H shift, freeze, panel 
lock 
POWER SOURCE:  100-240VAC, 50/60Hz, 14VA 
DIMENSIONS:  19 inch (W), 7 inch (D), 1U (H) rack mountable 
WEIGHT:  2.6 kg. (5.7 lbs.) approx. 
ACCESSORIES:  Power cord, Null-modem Adapter 
8  Communication Protocol 
RS-232 communication between the FC-4001 and the PC is performed using 
this protocol (VER-0.1), which uses four bytes of information, and data is at 
9600 baud, no parity, 8 data bits and 1 stop bit. 
The controller and the machine should be connected via a null-modem 
connection, that is, if using a DB-9 port, connect PIN 5 of the PC to PIN 5 of 
the machine, cross PINs 2 and 3, that is, connect PIN 2 of the PC to PIN 3 of 
the machine, and connect PIN 3 of the PC to PIN 2 of the machine. On the PC 
side, short PINs 4 and 6, and short PINs 1, 7 and 8. This protocol 
complements Kramer’s “Protocol 2000” (Kramer’s switcher protocol), that is, 
the two protocols can co-exist without disturbing one another (according to 
Protocol 2000’s definitions, the FC-4001 would be machine number 24). 
1 Specifications are subject to change without notice 