User's Manual
Restrictions:
1. Do not mount the unit on any kind
of metal surface.
2. Do not mount any input cable next
to the antenna (see figure).
Meter types:
1. There are two main types of meters:
2. Meters that produces a ‘Passive
Pulse’.
3. Meters that produces an ‘Active-
Pulse’ (known also as-‘’Pulse
Generator’).
Technical Specifications:
Operating Voltage 8–15 VDC
Standby Current 30µA max.
Tx Current 0.8A max.
Power Output 2W
Freq. Stability
±5ppm at
operating temp.
range
Operating Temp.
-22°F ÷ 120°F
(-30°C ÷ 60°C)
Storage Temp.
-40°F ÷ 158°F
(-40°C ÷ 70°C)
Weight 0.5 lb.
(230 gr.)
Wiring:
1. Connect the two polls of the Meter input
cable to the meter using a self-stripping
insulated connector (like 3M-Scotchlock
or equivalent).
2. Polarity: if a ‘Passive Pulse’ type meter
is connected, there is no polarity so the
wires can be connected in any order, if
an ‘Active Pulse’ type meter is
connected, there is a polarity and the
wires have to be connected in the
following order: Red wire to the
POSITIVE (+) poll and the Black wire
to the NEGATIVE (-) poll,
(see figure 4).
Figure 4: Wiring