Installation Manual

Setting Dialer Parameters
To establish communication between the
alarm panel and the dialer interface,
program the alarm panel with the
following parameters, and according to
the panel‘s instruction manual.
Set the communication parameters to the
following:
Data format: C-ID
Dialing method: DTMF only
Telephone #1: 11
Telephone #2: CMS
Account Number: For example 1234
Panel Phone Line: Enable telephone
line on panel (if necessary)
Telephone Line Cut
There is no need to connect the dialer
interface and program the PGM on the
alarm panel
In case of line trouble, the internal TLM
of the dialer interface performs two
operations:
Transmits a “Line fault” event
to the CMS
Changes the operation mode to
“no phone line”. In this mode
all events are transmitted via
radio. The dialer interface
changes to normal mode if the
line is restored.
Alarm Codes
If one of the inputs is activated an alarm
code is transmitted to the CMS.
The alarm codes are programmable, and
therefore, those shown here are
suggestions.
Additional codes are described in the
alarm panel user manual, according to
the C-ID format reporting codes.
Table 3: C-ID (LARS II) Alarm Codes
Alarm Type
Alarm Code
Medical
100
Fire Alarm
110
Panic Alarm
120
Duress
121
Burglary
130
Box Tamper
137
General Alarm
140
Sensor Tamper
144
24 Hr. Non-burglary
150
Special Code (KP)
170
AC Loss
301
Battery Test Failure
309
Battery Missing/Dead
311
RF Receiver Jam
Detected
344
Tel. Line Fault
351
RF Loss of Supervision
381
RF Low Battery
384
Open/Close
400
Open/Close by Key
409
2-way Communication
703
Note: Each sensor input can be programmed
with one alarm code.
Table 4: Input Zones (LARSII)
Input #
Alarm Zone
Reset Zone
Input 1
191
191
Input 2
192
192
Input 3
193
193
Input 4
194
194
Input 5
195
195
Input 6
196
196
Input 7
197
197
Input 8
198
198
Low battery
199
199
Warning:
Program Change
199
199
Program changed
199
199
Test
199
199
Communication
Fail
199
199
Table 5: Technical Specifications:
Operating Voltage
1015 VDC
Standby Current
15mA max.
Tx Current
1A max.
Power Output
3 W(VHF)/3W(UHF)
Spurious
-60 dB
Freq. Stability
5ppm at operating
temp. range
Modulation
FM FSK with PWM
Operating Temp.
-23F141F
(-30C60C)
Storage Temp.
-40F158F
(-20C70C)
Weight
190 gr
FCC
Approved
Frequency Range
UHF-Medium
430-470.9875 Mhz