Owner manual

14
Technical data
Faults
In case the unit does not heat the water, check for the possible reasons:
The guarantee does not cover the above repairs.
If there is a fault in the unit (the heater does not work and all the above reasons do
not occur), contact the nearest authorised service.
EPO water heater
4 5 6
Rated power
kW
4 5 6
Power consumption
kW
2 + 2 2,5 + 2,5 3 + 3
Rated voltage 230V~ / 400V 2N~
Rated current
A
17,4 (8,7)* 21,7 (10,9)* 26,1 (13,0)*
Supply water pressure
MPa
0,12 ÷ 0,6
Operating point l/min 1,2 1,5 1,8
Efciency (at Δt = 30°C) l/min 1,9 2,4 2,9
Overall dimension (height x width x depth)
mm
209 x 229 x 85
Weight
kg
~2,4
Fuse rated current
A
20 (10)* 25 (16)* 32 (16)*
Min. connecting wires section
mm
2
3x2,5 (4x1,5)* 3x4 (4x2,5)*
The maximum allowed network impedance
(0,32)** (0,29)**
Water supply pipe section G 1/2” (distance between inlet and outlet 110mm)
* - for 400V2N~
** - for 230V~
Fault Reason
control lights off
power supply failure
unit doesn’t heat up the water/
water temp. is too low
power supply failure
water ow rate is too low (e.g. lter is blocked with impurities,
improper water ow regulation)
there is no bridge connecting terminal clamps U and V
for single phase supply