Owner manual

18
Faults
In case the heater does not heat the water, check for possible reasons:
- a failure of the mains supplies (e.g. fuses),
- insufcient ow rate through the heater (e.g. dirty lter, incorrect setting of the
ow regulating valve) - see „Flow regulation”.
The warranty does not cover the above repairs.
If there is a fault in the appliance (the heater does not work and all the above reasons
do not occur), contact the seller.
Technical data
EPJ.P - ...... - shower
EPJ.P-....u - shower + washbasin
Water heater EPJ.P Primus 4,4 5,5
Rated power kW 4,4 5,5
Rated voltage 230V~
Rated current A 19,1 23,9
Min. supply water pressure MPa 0,12
Safety class IP25
Operating point l/min 1,8 2,2
Efciency (at Δt = 30°C) l/min 2,1 2,7
Overall dimension (height without tap set x width x depth)
mm 218 x 214 x 95
Weight (heater + ttings) kg 2,2 ÷ 0,6
Connection to the mains by supply cord (1,2m) mm
2
3 x 2,5
The maximum allowed network impedance 0,34 0,31
Water supply pipe section G1/2"