User's Manual
Sampling P0: Recording 0–8: Audio Input
577
Off (unchecked): The L/R (post-TFX) signals and the 
signals of the bus selected by Source Bus will be 
output from the L/R jacks and the headphone jack 
according to the Audio Input Bus Select (8–1b) and 
post-IFX Bus Select (8–5a) settings. This is the normal 
state.
Note: If Source Bus is L/R, this setting is ignored, and 
the L/R (post-TFX) signal will always be output from 
the L/R jacks and headphone jacks.
Pre Trigger REC [000…500ms]
If you want a portion of sound immediately before the 
start of sampling to be included in the recorded 
sample, set this parameter to specify the length.
When sampling with “Trigger” Threshold, sampling 
will start when the input signal exceeds the Level 
threshold level. However if the Level setting causes a 
portion of the attack to be lost, you can set the “Pre 
Trigger REC” parameter to capture the early attack as 
well.
When sampling with “Trigger” Sampling START SW, it 
is best to use “Metronome Precount” so that the 
instrumental performance etc. is sampled in tempo. If 
the performance is ahead of the tempo, this Pre Trigger 
REC parameter lets you sample without losing any of 
it.
If you increase this setting, you will always be 
sampling an unneeded portion ahead of the desired 
sample. Normally you should set this to 000 ms, and 
specify the minimum required length when 
necessary.
Trigger [Sampling START SW, Note On, Threshold]
Specifies how sampling will be initiated.
Sampling START SW: Pressing the SAMPLING REC 
switch will cause the OASYS to enter sampling-
standby mode, and sampling will begin when you 
press the SAMPLING START/STOP switch.
1. Press the SAMPLING REC switch to enter 
sampling-standby mode.
2. Use the “Recording Level [dB]” slider to adjust the 
sampling level.
3. Sampling will begin when you press the 
SAMPLING START/STOP switch.
(If you are using the “Metronome Precount” 
function, pressing the SAMPLING START/STOP 
switch will cause sampling to begin after the 
metronome sounds a count-down. If Metronome 
Setup “Bus (Output) Select” (0–8d) is set to L/R, the 
metronome will stop sounding at the moment that 
sampling begins.)
4. To stop sampling, press the START/STOP switch 
once again.
Sampling will also stop automatically if it continues 
to the specified “Sample Time” (0–1d).
If you want to apply an effect etc. to an existing sample 
and automatically create a new sample (Resampling), 
set “Trigger” to Sampling START SW, and set 
“Resample” (0–8c) to Auto.
Note On: Press the SAMPLING REC switch and then 
press the SAMPLING START/STOP switch to enter 
sampling-standby mode. Sampling will begin when 
you play the keyboard.
Sampling will also begin if a MIDI note-on is 
received (instead of playing the keyboard).
1. Perform steps 1 and 2 described above.
2. Press the SAMPLING START/STOP switch.
3. When you play the keyboard or when a MIDI 
note-on is received, sampling will start 
automatically.
4. To stop sampling, perform step 4, above.
Threshold: Sampling will begin automatically when 
the input level exceeds the specified “Level.”
1. Press the SAMPLING REC switch to enter 
sampling-standby mode.
2. Use the “Recording Level [dB]” slider to adjust the 
sampling level.
Be careful of changes in the monitoring volume. 
(“Recording Level [dB]” 0–8b)
3. Adjust the Level setting. The red triangles at both 
sides of the “Recording Level [dB]” level bar 
display will indicate the Level value.
Normally you will set this to a low a level as 
possible without allowing sampling to be triggered 
by noise.
4. Press the SAMPLING START/STOP switch. When 
the input level exceeds the Level you specified, 
sampling will begin automatically.
5. To stop sampling, press the START/STOP switch 
once again.
Alternatively, sampling will end automatically if it 
continues to the time specified for “Sample Time” 
(0–1d).
Metronome Precount [Off, 4, 8, 3, 6]
This specifies whether the metronome will sound a 
count-down before sampling begins. This can be set 
only if “Trigger” is set to Sampling START SW.
Off: Sampling will begin immediately when you press 
the SAMPLING START/STOP switch from recording-
standby mode.
4, 8, 3, 6: When you press the SAMPLING 
START/STOP switch from recording-standby mode, 
the metronome will count the specified number of 
beats at the “ (Tempo)” tempo, and then sampling will 
begin. If you set this to 4, sampling will begin on the 
count of 0 after a pre-count of 4–3–2–1–0.
The output destination and level of the metronome 
sound are specified by Metronome Setup (0–8d). If 
“Bus (Output) Select” is set to L/R, the metronome 
will stop sounding the instant sampling actually 
begins.
Resample [Manual, Auto]
Specifies how resampling will occur.
This can be set only if “Trigger” is set to Sampling 
START SW.
The process of sampling a sample (or samples) is called 
“resampling.”










