User manual
39
In-house manufacturing
Dependingupontheexistingplugsystem,theconnection
wirescanbemanufacturedbyanelectricianhimself.
a. Loosen the two screws
3
in the housing and lift o
lid
1
.
b. Openthestrainreliefclamp
5
andremovecompletely.
c. Cut the device supply wire at the desired point near
the device plug and strip the two ends of the wire.
• ThelengthofthewirebeforethePRCD-Smustbea
minimumof1.5m+10%.
• The length of the wire after the PRCD-S must be a
minimumof1.5m.
d. Strip single cores and install wire-end sleeves
(max.diameter2.5mm²).
e. Push the protective rubber sleeves
4
over the ends of
the wires.
f. Connect the connection cable to the terminal clamps
A
,
beginning with the ground wire.
g. Observe:inputside
(arrowdirection=directionofcurrentow)
h. Inputside:connectPhaseLtoterminal
C
, neutral wire
N to terminal
B
i. Output side: connect neutral wire N to terminal
B
,
PhaseLtoterminal
C
, ground wire PE to terminal
A
j. Attach the connecting wires and protective rubber
sleeves
4
with the strain relief clamps.
Check protective rubber sleeves and strain relief clamps
for proper fit.
k. Place the lid
1
on the housing
2
and tighten the screws
3
withatorqueof1Nm.
ThewirelengthsofthePRCD-Smadebythemanufacturer
can deviate from the dimensions listed above.
Repeat test
ThePRCD-Smustbecheckedregularly.
Instructions for this can be found at www.kopp.eu.