Use and Care Manual

with a minimum 6” overhang surrounding the fryer. A make-up air style is suggested, with a
built-in and tested fire protection system (e.g., Ansul™).
The appliances electrical schematic diagram is located inside the door.
Do not directly connect the fryer flue or exhaust to the ventilation hood.
Ensure the hood grease filters are at least 18” above the fryer exhaust flue.
FLUE INSTALLATION:

BEFORE USING FRYER INSTALL AND ASSEMBLE THE 10-5/8” FLUE AND
DEFLECTOR PLATE TO THE FRYER.
1. Unpack the flue box and flue wrap
2. Place the inner flue box over the flue and secure it with four self-tapping screws using a
5/16” socket
3. Slide the flue wrap over the inner flue [ Ensure the fryer is properly positioned under the
hood with proper overhang on all sides of the appliance – code requires ≥ a 6” hood overhang
distance]
4. Secure it with two self-tapping screws on the back and then secure it with two slotted head
M5 screws from front.