Use and Care Manual

2. Precautions & Recommendations
2.1 Transportation and Storage
During transportation, the machine should be handled with care and should not be turned upside
down to prevent damage to the shell and internal components. The packaged machine should be
stored in a well-ventilated warehouse free from corrosive gases. If it needs to be stored in an open-air
environment temporarily, measures should be taken to protect it from rain.
2.2 Notice for Installment
1. The installation of this device should only be carried out by professional technicians.
2. This device is suitable for use in areas with an altitude lower than 2000m.
If the altitude is higher than this, please contact the manufacturer for further instructions.
3. The connection of this device should comply with the provisions of gas safety, installation, and usage.
4. The device should be kept at a minimum clearance of 10cm away from non-combustible
objects on both sides and 20cm at the back (e.g., walls, windows, etc.).
Do not install it on a flammable floor or other combustible objects.
For ranges with a convection-type oven, a minimum clearance of 10cm must be allowed behind
the motor and the rear non-combustible enclosure to provide adequate air circulation to prevent
the motor from overheating.
5. Due to the weight of the device, it should be installed on the floor.
6. Level the device using a level gauge, and adjust the height using the adjustable feet.
For griddles, adjust the feet to make the griddle plate horizontal before use.
7. The mounting position should be well-ventilated and have ventilation facilities to ensure
that all burnt gases produced during the combustion process are completely exhausted.
8. After installation, ensure that the device is level and stable. It should not sway or tilt during operation.
9. A quick-acting gas valve for switching off should be installed upstream of the device in an easily
accessible location before installation.
10. Ensure that the gas supplied to the device is the same as the gas it is designed to use.
If not, please do not use it.
11. Do not use gas that is not appropriate for this device as fuel. Neither high-pressure regulating
valves nor medium-pressure regulating valves are suitable.
(This device is only suitable for low-pressure regulating valves.)
12. The pipeline connecting to the device should be connected with proper metal pipes
to ensure that there is no leakage.
13. If the pipeline pressure is 10% higher or lower than the rated pressure,
install a pressure regulator to adjust the gas pressure to the rated pressure.
14. After connecting the device to the gas system, check for leaks at joints and pipe fittings
using soapy water or a specific leak detector (spray). Do not use an open flame for testing.
15. Check the gas supply pressure after installation.
3