BASIC CABINET SETUP
A. Electrical Requirements: Please consult the DATA PLATE for electrical specifics. Note that cabinets rated at
120V and 1500 watts require a 125 VAC, 15 amp receptacle, and must be operated on an individual branch
circuit. DO NOT MODIFY THE CORD PLUG under any circumstances.
B. Power Setup: With the POWER switch in the OFF position, connect the cabinet to a grounded 125 VAC receptacle.
C. Water Pan Maintenance: If Proofing or Holding with moisture, fill the water pan to the top using clean, HOT tap
water. Check the water level every 3 hours (or every 2 hours during Proofing) and refill as necessary with clean, HOT
tap water. The water pan does not require filling for Heating.
HEATING INSTRUCTIONS
1. Mode Setting: Rotate the Combination Module switch to HEAT.
2. Power Setting: Turn the POWER switch to the ON position. The power indicator light will illuminate.
3. Initial Temperature Control: Set the TEMPERATURE control to 9.
4. Pre-Heating: Pre-heat the cabinet until your desired temperature is achieved.
Typically, the heat-up time from 77°F (25°C) ambient temperature to 160°F (71°C) is approximately 45 minutes.
For a cabinet with insulation, the typical heat-up time to 185°F (85°C) is also around 45 minutes.
5. Temperature Adjustment: Re-set the TEMPERATURE control and adjust as necessary to reach your desired
temperature. For a temperature between 150°F (66°C) to 160°F (71°C), a setting between 6 and 8 is typical.
PROOFING INSTRUCTIONS
A. Mode Setting: Rotate the Combination Module switch to PROOF.
B. Power Setting: Turn the POWER switch to the ON position. The power indicator light will illuminate.
C. Initial Temperature Control: Set the TEMPERATURE control to the desired level.
D. Humidity Control: Set the HUMIDITY control to 9.
E. Pre-Heating: Pre-heat the cabinet until the desired temperature and humidity levels are achieved.
Typically, the heat-up time from 77°F (25°C) ambient temperature to 95°F (35°C) and 95% relative humidity is approxi-
mately 30 minutes.
F. Adjustments: Tweak the temperature and humidity settings as necessary to reach your desired levels.
OPERATING INSTRUCTIONS
(*Heat Only Models)