User guide
Wiring Harness
Pump
CAUTION: Improperly connecting the speed controller can damage it, the 
pump, or the power supply. Ensure that total device load does not exceed the 
maximum rating of the controller (36W@12VDC, 50W@24VDC). Ensure that 
the connected device will safely accept the voltage being supplied (12V or 24V 
depending on the jumper setting).
!
CTR-SPD1224M Installation Guide v 1.0
1
Power In
(12VDC)
2
Power Out
(Pump, Fan, etc.)
The Koolance CTR-SPD1224M uses voltage control 
to throttle speeds for 12VDC pumps or fans. With a 
jumper setting, it will also step-up and throttle volt-
age for 24VDC devices. CTR-SPD1224M requires 
a 12VDC input.
Do not operate components at voltages which exceed 
their specifications. Running a 12V-max pump at 24V 
from the speed controller can damage the pump.
To avoid damaging the speed controller, do not con-
nect devices which exceed the controller’s maximum 
power rating (36W@12V, 50W@24V).
For 3-pin pumps or fans, connect this to the 
available plug on the wiring harness.
Use the wiring harness included with 
your speed controller. This will accept 
the pump or fan connection.
For pumps with larger Molex connectors, 
use the larger (2-wire, 4 position) connector 
on the wiring harness.
Power Supply
Pump tachometer signals are not used by the speed 
controller. If your pump has an integrated speed knob, 
it should be left on the maximum setting when adjusting 
speed via the Koolance controller.
Pumps with built-in control 
should be left on maximum 
speed
CTR-SPD1224M has a jumper to select from 12V 
(max) or 24V (max) speed control.
CAUTION: Do not power 12V pumps or 
other devices with the 24V setting! This 
can permanently damage the attached 
device.
!
Wiring Harness
Connect One 
to Pump
Connect to 
Controller
Voltage Jumper
3-pin Pump 
or Fan
Wiring Harness
Connect the 3-pin plug from the wiring har-
ness to the controller.
Finally, connect the power supply to the 
controller.