User Manual

31
The maximum calculated production is based on ambient temperature and a water temperature of 50 ℉.
There may be deviations depending on the installation conditions, which may become severe during
high temperature periods, such as summer.
Specifications
Item UNIT
Specifications
KCU-180-AH
Maximum
ice making capacity
lb
/day
177
Cooling capacity
90F
Ice cubes are produced 30 minutes after powering on
Storage capacity lb 77
Dimensions W x D x H
(including feet)
inch 26.0 x 27.3 x 39.0
Power source
Single
phase
115 V / 60 Hz
Rated current A 7.0
Packing
Before
lb
154.3
After 171.9
Freezing
capability
Refrigerant GAS R-404A
Condenser
Air
cooling
Fin-tube type
Ice shape
-
Half dice
Size of ice / quantity inch
0.4"w
x 0.875"d x 1.14"h / 180
Cooling method
-
Air cooled model
Ice thickness control
-
High water level sensor
Ice delivery control
-
Low water level sensor
Ice fill-up
detection control
-
Bin full sensor
High pressure
switch sensor
-
Automatic recovery based on high pressure switch(HPS)
Time control MICOM-CONTROL
Operating temperature -
Temperature of supplied water : 50 ~ 90℉
Ambient temperature : 50 ~ 100℉ Water
pressure :
20 ~ 80 psig