Owner manual
VMP3 NetBootLoader
ID 29230, Rev. 01 © 2005 Kontron Modular Computers GmbH Page 5 - 37
29230.01.UG.VC.050727/091440
P R E L I M I N A R Y
SL
FUNCTION: Download Motorola S-Records to data buffer
SYNTAX:
sl [-o[=]<offset>] [-u]
where:
sl command
-o option: offset
<offset> parameter: value: hexadecimal: unsigned
offset to be subtracted from each record's address
-u option: source = SER0 instead of TERM
DESCRIPTION: With the command “sl” Motorola S-Records are downloaded to the
data buffer and the record addresses modified accordingly as
required for SDRAM operation (for copying to 0x0).
The “<offset>” parameter may be used to change the record base to
0x0.
The “-u” option selects the SER0 interface as source for the S-
Records otherwise the TERM interface is used..
USAGE:
Download S-Records to data buffer and reduce each record’s address by
0x10000.
COMMAND / RESPONSE (none):
sl -o=10000