Manual

VMP2 VMP1-IO1 Module (Optional)
ID 24855, Rev. 02Page A - 12 © 2002 PEP Modular Computers GmbH
A.8 Jumper Setting
The jumper settings of the IO1 module depend on the module’s position relative to the
VMP2 and other modules, if any (please see Figure A4 below).
Table A-4: IO1 Jumper Settings for Different Module Positions
IDSEL Clock GNT# REQ#
J12J11J10J1J2J3J4J5J6J7J8J9
Position 1 Set Open Open Set Open Open Set Open Open Set Open Open
Position 2 Open Set Open Open Set Open Open Set Open Open Set Open
Position 3 Open open Set Open Open Set Open Open Set Open Open Set
Note:
Position 1 refers to the settings applicable when 1 module (IO1 or
other) is attatched to the VMP2.
Position 2 refers to the settings applicable when 2 modules (IO1
or other) are attatched to the VMP2.
Position 3 refers to the settings applicable when 3 modules (IO1
or other) are attatched to the VMP2.
Important!
: Position 3 has not yet been tested and approved by
PEP and is not recommended for use in this issue of the manual.