Manual
VM62(A) / VM42(A) User’s Manual Chapter 3 Configuration
3.1.1 Jumper J1: VME-SYSCLK
Setting Description
Set SYSCLK connected to VME Default
Open SYSCLK disconnected from VME
3.1.2 Jumper J2: VME-SYSRES
Setting Description
Set On-board RESET generator to VME Default
Open On-board RESET disconnected from VME
3.1.3 Jumper J8: VME Boot (VBOOT)
Setting Description
Set Boot from VME enabled
Open Boot from VME disabled Default
3.1.4 Jumper J9: AutoBahn Boot (ABOOT)
Setting Description
Set Boot from MP memory interface enabled
Open Boot from MP memory interface disabled Default
3.1.5 Jumper J14: Connection of Protective and Signal GND
Setting Description
Set Signal GND connected to Protective GND
Note: Care must be taken to avoid grounding current if this jumper
is set.
Open Signal GND not connected to Protective GND Default
May 17, 1996 © 1995 PEP Modular Computers Page 3-3