CP6925 CPCI 16 Channel Gigabit Ethernet Switch 6U Board, PICMG 2.16 User Guide PRELIMARY Doc.ID: 35008, Rev. 1.
CUSTOMER SPECIFIC Preface CP6925 Revision History Publication Title: CP6925: CPCI 16 Channel Gigabit Ethernet Switch, 6U Board PICMG 2.16 Doc.ID: 35008 Rev. PRELIMARY 1.0 Brief Description of Changes Date of Issue Initial issue 27-NOV-2006 Imprint Kontron Modular Computers GmbH may be contacted via the following: MAILING ADDRESS TELEPHONE AND E-MAIL Kontron Modular Computers GmbH +49 (0) 800-SALESKONTRON Sudetenstraße 7 sales@kontron.
CUSTOMER SPECIFIC CP6925 Preface Revision History .........................................................................................................ii Imprint ........................................................................................................................ii Disclaimer ..................................................................................................................ii Table of Contents ..........................................................................
CUSTOMER SPECIFIC Preface CP6925 2.3.2 Gigabit Ethernet ..............................................................................2 - 9 2.3.3 Ethernet Operational Status LEDs ..................................................2 - 9 2.4 Power Supply .........................................................................................2 - 10 3. Installation ................................................................................ 3 - 3 3.1 Safety Requirements ............................
CUSTOMER SPECIFIC CP6925 Preface List of Tables System Relevant Information ................................................................... 1 - 5 1-2 Main Specifications ................................................................................ 1 - 10 1-3 Applied Standards .................................................................................. 1 - 11 1-4 Related Publications ..............................................................................
CUSTOMER SPECIFIC Preface CP6925 PRELIMARY This page has been intentionally left blank. Page vi Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 Preface List of Figures CP6925 Application System Interfacing Diagram .................................... 1 - 6 1-2 CP6925 System Level Interfacing Diagram ............................................. 1 - 7 1-3 CP6925 Front Panel ................................................................................ 1 - 8 1-4 CP6925 Board Layout (Top View) ............................................................ 1 - 9 2-1 CP6925 Board Level Interfacing ....................
CUSTOMER SPECIFIC Preface CP6925 PRELIMARY This page has been intentionally left blank. Page viii Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 Preface Proprietary Note This document contains information proprietary to Kontron. It may not be copied or transmitted by any means, disclosed to others, or stored in any retrieval system or media without the prior written consent of Kontron or one of its authorized agents. The information contained in this document is, to the best of our knowledge, entirely correct.
CUSTOMER SPECIFIC Preface CP6925 Explanation of Symbols Caution, Electric Shock! This symbol and title warn of hazards due to electrical shocks (> 60V) when touching products or parts of them. Failure to observe the precautions indicated and/or prescribed by the law may endanger your life/health and/or result in damage to your material. Please refer also to the section “High Voltage Safety Instructions” on the following page.
CUSTOMER SPECIFIC CP6925 Preface For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation.
CUSTOMER SPECIFIC Preface CP6925 General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the device, which are not explicitly approved by Kontron and described in this manual or received from Kontron’s Technical Support as a special handling instruction, will void your warranty.
CUSTOMER SPECIFIC CP6925 Preface Two Year Warranty Kontron grants the original purchaser of Kontron’s products a TWO YEAR LIMITED HARDWARE as described in the following. However, no other warranties that may be granted or implied by anyone on behalf of Kontron are valid unless the consumer has the express written consent of Kontron.
CUSTOMER SPECIFIC Preface CP6925 PRELIMARY This page has been intentionally left blank. Page xiv Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Introduction Chapter 1 Introduction Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Introduction CP6925 PRELIMARY This page has been intentionally left blank. Page 1 - 2 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 1. Introduction 1.1 System Overview Introduction The CompactPCI board described in this manual operates using the CompactPCI PICMG specification 2.16, CompactPCI Paket Switching Backplane. For further information regarding this CompactPCI standard and its use, visit the home page of the PCI Industrial Computer Manufacturers Group (PICMG).
CUSTOMER SPECIFIC Introduction 1.2 Board Overview 1.2.1 Board Introduction CP6925 The CP6925 Gigabit Ethernet switch is a 6U/4HP, unmanaged layer 2, Ethernet fabric board designed for use with CompactPCI PICMG 2.16 packet switching backplane (PSB) systems. The CP6925 provides 16 channels of Gigabit Ethernet: 14-channels on the backplane and two channels on a dual RJ45 connector at the front panel. It supports 10, 100, and 1000 Mbit/s data transfer rates.
CUSTOMER SPECIFIC CP6925 1.3 Introduction System Relevant Information The following system relevant information is general in nature but should still be considered when developing applications using the CP6925. System Relevant Information SUBJECT INFORMATION System Configuration The CP6925 may be used in any CompactPCI PICMG 2.16 PSB system. Board Location in the System The CP6925 board may only be installed in a fabric slot. Hot Swap Compatibility The CP6925 is not Hot Swap capable.
CUSTOMER SPECIFIC Introduction 1.4.1 CP6925 Application System Interfacing Figure 1-1: CP6925 Application System Interfacing Diagram Application System (AS) CompactPCI PSB System PRELIMARY CP6925 PSB PSB BP NODES BP NODES AS Processes Page 1 - 6 CP6925 AS Processes Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 1.4.2 Introduction System Level Interfacing Figure 1-2: CP6925 System Level Interfacing Diagram CompactPCI PSB System CP6925 J5 TX LP01...08 RX TX LP09...14 RX PRELIMARY J3 GIGABIT ETHERNET SWITCH LP01...08 TX RX J3 LP09...14 TX 15 16 RX J5 J6A/B J3 and J5 provide fabric interfacing to the PSB for the BP nodes TSE J6A and J6B provide two external uplinking interfaces Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Introduction 1.4.3 CP6925 Front Panel Figure 1-3: CP6925 Front Panel PRELIMARY LEGEND FOR THE LEDS: LED COLOR FUNCTION Activity green Blinks when activity takes place on the corresponding link: LP01 to LP14, channels 15 and 16 Speed LED off Link speed is 10 Mbits/s green Link speed is 100 Mbit/s yellow Link speed is 1000 Mbit/s activity LEDs speed LEDs Page 1 - 8 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 1.4.4 Introduction Board Layout Figure 1-4: CP6925 Board Layout (Top View) MAG A J6 B TXRX J5 MAG TXRX MAG D16 GbE SW TXRX MAG J3 MAG TXRX D1 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Introduction 1.5 CP6925 Technical Specifications Table 1-2: Main Specifications PRELIMARY TYPE SPECIFICATIONS Controller Broadcom® BCM5396, 16-port Gigabit Ethernet Switch with integrated SerDes/ SGMII interfacing, operates in unmanaged mode, layer 2 Ethernet 14 channels of fabric three speed Ethernet: 10/100/1000 Mbit/s 2 channels of Gigabit Ethernet, routed to the front panel Ethernet Interfaces Two CPCI backplane connectors: J3 and J5, fabric PICMG 2.
CUSTOMER SPECIFIC CP6925 1.6 Introduction Applied Standards The Kontron Modular Computers’ CompactPCI module CP6925 complies with the requirements of the following standards: Table 1-3: Applied Standards TYPE CE STANDARD Emission EN55022, EN61000-6-3 Immunity, Industrial Environment EN61000-6-2 Immunity, IT Equipment EN55024 Electrical Safety EN60950-1 Note: The CP6925 is specified I/O only for: SELV and EVL. MECHANICAL ENVIRONMENTAL 1.7 Mechanical Dimensions IEEE1101.
CUSTOMER SPECIFIC Introduction CP6925 PRELIMARY This page has been intentionally left blank. Page 1 - 12 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Functional Description Chapter 21 Functional Description Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Functional Description CP6925 PRELIMARY This page has been intentionally left blank. Page 2 - 2 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 2. Functional Description Functional Description The following chapters present more detailed, board level information about the CP6925 whereby the board components and their basic functionality are discussed in general. 2.1 General Information The CP6925 is designed as a 16 channel Gigabit Ethernet Switch board with interfacing for front panel connectors as well as supporting fabric interfacing on the J3 and J5 backplane connectors.
CUSTOMER SPECIFIC Functional Description CP6925 Figure 2-1: CP6925 Board Level Interfacing CP6925 J3 J5 PRELIMARY RX LP09...14 RX J1 LP01...08 M AG MAG RX RX POWER GIGABIT ETHERNET SWITCH TX TX TXRX M AG MAG M AG LP09...14 J5 Page 2 - 4 TX LP01...08 J3 TX 16 15 A J6 B Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 2.3 Interfaces 2.3.1 CompactPCI Bus Interface The complete CompactPCI connector configuration comprises three connectors designated as J1, J3, and J5. Functional Description Figure 2-2: CPCI Connectors J1/J3/J5 22 Their function is as follows: • J1: Power only: 5V and 3.3V • J3: Fabric link ports: LP01 to LP08 • J5: Fabric link ports: LP09 to LP14 CompactPCI Connector Keying CompactPCI connectors support guide lugs to ensure a correct polarized mating.
CUSTOMER SPECIFIC Functional Description 2.3.1.2 PRELIMARY Table 2-1: CP6925 CompactPCI Connector J1 CompactPCI Bus Connector J1 Pinout PIN ROW Z ROW A ROW B 25 NC 5V NC NC 3.3V 5V GND 24 NC NC 5V V(I/O) NC NC GND 23 NC 3.3V NC NC 5V NC GND 22 NC NC GND 3.3V NC NC GND 21 NC 3.3V NC NC NC NC GND 20 NC NC GND V(I/O) NC NC GND 19 NC 3.3V NC NC GND NC GND 18 NC NC GND 3.3V NC NC GND 17 NC 3.
CUSTOMER SPECIFIC CP6925 Table 2-2: CompactPCI Connector J3 CompactPCI Bus Connector J3 Pinout PIN ROW Z 19 NC NC NC GND NC NC GND 18 NC NC NC GND NC NC GND 17 NC NC NC GND NC NC GND 16 NC LP8_DA+ LP8_DA- GND LP8_DC+ LP8_DC- GND 15 NC LP8_DB+ LP8_DB- GND LP8_DD+ LP8_DD- GND 14 NC LP7_DA+ LP7_DA- GND LP7_DC+ LP7_DC- GND 13 NC LP7_DB+ LP7_DB- GND LP7_DD+ LP7_DD- GND 12 NC LP6_DA+ LP6_DA- GND LP6_DC+ LP6_DC- GND 11 NC LP6_DB+ LP6_DB- GND
CUSTOMER SPECIFIC Functional Description 2.3.1.
CUSTOMER SPECIFIC CP6925 Gigabit Ethernet Figure 2-3: Dual Gigabit Ethernet Connector J6A/B The CP6925 board includes two 10Base-T/100BaseTX/1000Base-T Ethernet ports. CH The Ethernet connectors are realized as RJ45 connectors. The interfaces provide automatic detection and switching between 10Base-T, 100Base-TX and 1000Base-T data transmission (Auto-Negotiation). Auto-wire switching for crossed cables is also supported (Auto-MDI/X).
CUSTOMER SPECIFIC Functional Description 2.4 CP6925 Power Supply PRELIMARY The CP6925 is designed to be able to generate its own 3.3V power from the 5V input power from the backplane. If required, 3.3V power, however, can be obtained from the backplane. This can be especially advantageous in systems where it is necessary to balance the power supply loading. Please contact Kontron to clarify the system requirements before ordering the CP6925. Page 2 - 10 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Installation Chapter 31 Installation Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC Installation CP6925 PRELIMARY This page has been intentionally left blank. Page 3 - 2 Doc.ID: 35008, Rev 1.
CUSTOMER SPECIFIC CP6925 3. Installation Installation The CP6925 has been designed for easy installation. However, the following standard precautions, installation procedures, and general information must be observed to ensure proper installation and to preclude damage to the board, other system components, or injury to personnel. 3.1 Safety Requirements The following safety precautions must be observed when installing or operating the CP6925.
CUSTOMER SPECIFIC Installation 3.2 CP6925 CP6925 Installation Procedures The following procedures are applicable the installation of the CP6925 in a system. Procedures for standard removal are found in its respective chapter. To perform an installation of the CP6925 in a system proceed as follows: 1. Ensure that the safety requirements indicated in Chapter 3.1 are observed. Warning! Failure to comply with the instruction below may cause damage to the board or result in improper system operation.
CUSTOMER SPECIFIC CP6925 3.3 Installation Standard Removal Procedures To remove the board proceed as follows: 1. Ensure that the safety requirements indicated in Chapter 3.1 are observed. Warning! Care must be taken when applying the procedures below to ensure that neither the CP6925 nor system boards are physically damaged by the application of these procedures. Ensure that no power is applied to the system before proceeding. Disconnect any interfacing cables that may be connected to the board.
CUSTOMER SPECIFIC Installation CP6925 PRELIMARY This page has been intentionally left blank. Page 3 - 6 Doc.ID: 35008, Rev 1.