User guide
CP6003-SA/RA/RC IPMI Firmware
ID 1045-5656, Rev. 2.0 Page 19
P R E L I M I N A R Y
[1] Has OEM extensions. Please refer to 6.1, Get Device ID Command with OEM Extensions.
Partial Add SEL Entry 40.7 Storage 45h O / No
Delete SEL Entry 40.8 Storage 46h
O / Yes
Clear SEL 40.9 Storage 47h
O / Yes
Get SEL Time 40.10 Storage 48h
O / Yes
Set SEL Time 40.11 Storage 49h
O / Yes
Get Auxiliary Log Status 40.12 Storage 5Ah O / No
Set Auxiliary Log Status 40.13 Storage 5Bh O / No
LAN DEVICE COMMANDS O
Set LAN Configuration Parameters 23.1 Transport 01h
O / Yes
Get LAN Configuration Parameters 23.2 Transport 02h
O / Yes
Suspend BMC ARPs 23.3 Transport 03h O / No
Get IP/UDP/RMCP Statistics 23.4 Transport 04h
O / Yes
SERIAL/MODEM DEVICE COMMANDS O
Set Serial/Modem Configuration 25.1 Transport 10h O / No
Get Serial/Modem Configuration 25.2 Transport 11h O / No
Set Serial/Modem Mux 25.3 Transport 12h O / No
Get TAP Response Codes 25.4 Transport 13h O / No
Set PPP UDP Proxy Transmit Data 25.5 Transport 14h O / No
Get PPP UDP Proxy Transmit Data 25.6 Transport 15h O / No
Send PPP UDP Proxy Packet 25.7 Transport 16h O / No
Get PPP UDP Proxy Receive Data 25.8 Transport 17h O / No
Serial/Modem Connection Active 25.9 Transport 18h O / No
Callback 25.10 Transport 19h O / No
Set User Callback Options 25.11 Transport 1Ah O / No
Get User Callback Options 25.12 Transport 1Bh O / No
SOL Activating 26.1 Transport 20h
O / Yes
Get SOL Configuration Parameters 26.2 Transport 21h
O / Yes
Set SOL Configuration Parameters 26.3 Transport 22h
O / Yes
Note ...
Some of the above-mentioned commands, such as SDR commands, work
only if the IPMI controller is configured as BMC. For further information, refer
to the IPMI specification 2.0.
Table 3: Standard IPMI Commands (Continued)
COMMAND
IPMI 2.0
SPEC.
SECTION
NETFN CMD
KONTRON
SUPPORT
ON IPMI
CONTROLLER