Instruction Manual

CP372 Configuration
ID 25780, Rev. 01 © 2002 Kontron Modular Computers GmbH Page 4 - 13
25780.01.VC.021121/111238
P R E L I M I N A R Y
4.3.4 Common Board Registers
These registers are for internal test and debug only. The Common Status Register contains
Logic Version and PCB Version. The Common Control Register is a read/write register without
any further functionality. Neither of these should be used by standard software.
Note: The HW version starts with 0, Logic Version with 1. It will be incremented for each re-
leased version.
Table 4-9: ROM Data Register Bit Map
BITS TYPE DEFAULT FUNCTION
31-8 R/W 0 reserved
7-0 R/W 0 Data (for data read and write commands)
Table 4-10:Hardware Debug Register Bit Map
BITS TYPE DEFAULT FUNCTION
31-0 R/W 0 reserved
Table 4-11:Hardware Status Register Bit Map
BITS TYPE DEFAULT FUNCTION
31 - 16 R 0 reserved
15 - 8 R 00 HW Version (PCB Index)
7 - 0 R 01 Logic Version