Instruction Manual
CP372 Introduction
ID 25780, Rev. 01 © 2002 Kontron Modular Computers GmbH Page 1 - 11
25780.01.VC.021121/111237
P R E L I M I N A R Y
Note:
BEST CASE ACCURACY: best case calibration (not supported by Kontron)
ACCURACY: calibration by Kontron (at delivery)
Table 1-5: CP372 Accuracy
OUTPUT
SIGNAL
-
TYPE
and
RANGE
SIGNAL ACCURACY
at 23°C
± % of
FULL SCALE
ACCUMULATING
DEVIATION
% per K
(S and E1 BOARDS)
ACCUMULATING
DEVIATION
% per K
(E2 BOARDS)
BEST CASE ACCURACY
0 V – 5 V 0.05 0.001 0.001
0 V – 10 V 0.05 0.001 0.001
- 5 V – + 5 V 0.05 0.001 0.001
- 10 V – + 10 V 0.05 0.001 0.001
0 mA – 20 mA 0.1 0.002 0.002
ACCURACY
0 V – 5 V 0.05 0.001 0.001
0 V – 10 V 0.075 0.001 0.001
- 5 V – + 5 V 0.075 0.001 0.001
- 10 V – + 10 V 0.1 0.001 0.001
0 mA – 20 mA 0.1 0.002 0.002