Manual

Introduction CP-RIO3-05
Page 1 - 8 ID 1044-0711, Rev. 1.0
P R E L I M I N A R Y
In addition, modules providing ruggedized service comply with the following standards as well.
1.5 Related Publications
The following publications contain information relating to the CP-RIO3-05.
Table 1-3: Additional Standards for Modules Providing Ruggedized Service
TYPE ASPECT STANDARD REMARKS
Environmental Vibration
(Sinusoidal)
IEC60068-2-6 Ruggedized version test parameters:
10-300 (Hz) frequency range
5 (g) acceleration
1 (oct/min) sweep rate
10 cycles/axis
•3 axis
Single Shock IEC60068-2-27 Ruggedized version test parameters:
30 (g) acceleration
9 (ms) shock duration half sine
3 number of shocks per direction (total: 18)
6 directions
5 (s) recovery time
Permanent Shock IEC60068-2-29 Ruggedized version test parameters:
15 (g) acceleration
11 (ms) shock duration half sine
500 number of shocks per direction
6 directions
5 (s) recovery time
Table 1-4: Related Publications
PRODUCT PUBLICATION
CompactPCI Systems and
Boards
CompactPCI Specification 2.0, Rev. 3.0
Kontron CompactPCI Backplane Manual, ID 24229
All Kontron products Product Safety and Implementation Guide, ID 1021-9142