Owner's manual
Software Description
79 AT8404 User Guide
www.kontron.com
4.3.2.12 CmdGetStoragePortSelection
This command reads the current setting of the storage switch between AMC B4 and AMC B1/AMC B3.
4.3.2.13 CmdSetStoragePortSelection
Command Name NetFn LUN Command Number
CmdGetStoragePortSelection 0x30 3 0x91
Byte Num Data Field
Request Data 1...5
Token:
0xAB - (~T)
0xCA - (~5)
0xCC - (~3)
0xCF - (~0)
0xC8 - (~7)
6
Device:
0 – switch located at AMC B4
Response Data 1 Completion Code
2
Setting:
0 - the AMC B4 (port 2) is connected to AMC B1 (port 3)
1 - the AMC B4 (port 2) is connected to AMC B2 (port 2)
Command Name NetFn LUN Command Number
CmdSetStoragePortSelection 0x30 3 0x92
Byte Num Data Field
Request Data 1...5
Token:
0xAB - (~T)
0xCA - (~5)
0xCC - (~3)
0xCF - (~0)
0xC8 - (~7)
6
Device:
0 - switch located at AMC B4
7
Setting:
0 - the AMC B4 (port 2) is connected to AMC B1 (port 3)
1 - the AMC B4 (port 2) is connected to AMC B2 (port 2)
Response Data 1 Completion Code